The automatic Cleveland module conforms precisely to national and international Cleveland open cup flash point test methods. It comprises a sample cup, temperature probe, flash/fire detector, and a DIPS pod containing the sweeping mechanism with co-axial gas/electric ignitor.
The Cleveland module must be used with the Multiflash Automatic Flash Point – Universal Base Unit (34000-0). The base unit recognizes that the Cleveland module is connected and instantaneously sets up standard test parameters and calibration data.
Features
- Fully self-contained flash/fire point test module
- Ambient to 400 °C
- Gas or electric ignition
- Automatic heating control, flash and fire detection
- Automatic test results & end of test audible warning
- Automatic snuffer
- Automatic barometric correction
Additional Info
The flash point test area consists of a removeable sample cup in a thermal insulation ring, and a probe block for mounting the flash/fire
detector and sample temperature probe. The sample cup is heated by the hotplate within the Multiflash Automatic Flash Point - Universal
Base Unit (34000-0).
The DIPS pod contains the ignitor sweeping mechanism with a coaxial gas jet/electric hot wire ignitor, and a
snuffer that extinguishes any flames in the sample cup at the end of the test.
The sample temperature probe is a class A PRT, and
flash/fire detection is by an ionization ring.
Safety features include an initial sweep to check that the sample is below its flash
point at the start of the test and a PRT check to ensure that the correct probe is connected and is immersed in sample. When in search
mode, the software limits the maximum temperature to 50 °C above "expected flash". The snuffer automatically deploys at the end of the
test or if the independent fire detection probe (mounted over the test area) detects a flame. The hotplate in the Multiflash Automatic
Flash Point - Universal Base Unit (34000-0) is equipped with a cut-out to protect against over-temperature.
The optional Cooling
Boost Accessory (34008-0) allows the test area to be rapidly cooled in between tests by a blast of compressed air.
Supplied
with:
DIPS Pod
Test Area
Ignitor
Ionization ring flash detector
Fire detector
Sample PRT
Sweep arm setup
tools
Interconnection cables
Instruction manuals
Temperature Range |
Ambient to 400 °C |
Bath |
N/A |
Heating |
Hotplate |
Post Test Cooling |
Fan assisted or Forced Air (Requires 34008-0 Cooling Boost Module option) |
Post Test Cool-down Time (90°C to 50°C) |
9 minutes (Fan) |
Ignitor |
Quick-fit coaxial gas jet / electric hot wire, user selectable |
Temperature Probe |
Class A Platinum Resistance Thermometer, °C or °F |
Flash / Fire Detection |
Ionisation Ring |
Gas Supply (gas jet ignitor) |
Laboratory gas, 3 kPa (0.44 psi) maximum pressure |
Air Supply (forced air cooling |
Dry compressed air, 670 kPa (100 psi) maximum pressure |
Voltage |
110/120 V or 220/240 V, 50/60 Hz, (switchable) |
Power |
1 kW |
Size (HxWxD) |
330 x 470 x 420 mm |
Weight |
12 kg |
CCCN Code |
Tariff 90268020 |